| | 1.Low price and high reliability 2.105 output capacitor 3.AC input power suitable for the world 4.High efficiency and low operation temperature 5.Soft-start current can reduce the AC input impact effectively 6.With short-circuit and overload protection 7.Compact size, light weight 8.100% full-load burning test 9.Installed with EMI filter minimum wave | Model Specification | SP-500-12 | SP-500-13.5 | SP-500-15 | SP-500-24 | SP-500-27 | SP-500-48 | DC output voltage | 12V | 13.5V | 15V | 24V | 27V | 48V | Output voltage error | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | Rated output current | 40A | 36A | 32A | 20A | 18A | 10A | Output current rage | 0-40A | 0-36A | 0-32A | 0-20A | 0-18A | 0-10A | Wave and noise | 240mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 200mVp-p | 300mVp-p | Inlet stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | Load stability(Note5) | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | DC output power | 480W | 486W | 480W | 480W | 486W | 480W | Efficiency | 84% | 84% | 83% | 85.5% | 86.5% | 87% | Adjustable range for DC voltage | 10-13.2V | 12-15V | 13.5-18V | 20-26.4V | 24-30V | 41-56V | AC input voltage range | 88132VAC/176264VAC BY SWITCH 4763Hz;124370VDC | AC Input current | 7A/115V 3.5A/230V | Power Factor | 0.95/100240VAC | AC impulse current | 18A/115V 36A/230V | Leakage current | <3.5mA/240VAC | Overload protection | 105%135% TypePULSING HICCUP SHUTDOWN Reset: auto recovery | Over-voltage protection | 13.816.2V | 15.518.2V | 1821V | 27.632.4V | 3136.5V | 57.667.2V | Fan control,O.T.P. | RTH1 OR RTH2>=50 FAN ON,<=45 FAN OFF,>=70 PULSING HICCUP SHUTDOWN | Temperature coefficient | ±0.03%(050) | Setup rise hold up time | 1.5s,50ms,20ms | Vibration | 10500Hz,2G 10min./1cycle,Period for 60min,EACH AXES | Withstand voltage | Input and output interval3KVAC,Input and enclosure1.5KVAC Output and enclosure0.5KVAC | Isolation resistance | Input and output interval,Input and enclosure,Output and enclosure500VDC/100M Ohms | Working temperature and humidity | -10+50,20%90%RH | Store temperature and humidity | -20+85,10%95%%RH | Overall dimension | 185*20*93mm | Weight | 1.8Kgs | Safety standards | UL1950,TUV EN60950 | EMC standards | IEC1000-42,3,4,5,6,8,11 IEC100-3-2 | Note: 1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity 2.Error,include the setting error, line stability and load stability.(Note:5) 3.Wave test:adoptingA12double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting 4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage. 5.Load stability test: The load is from 0% to 100%,others 60%. 6.C2311must be knocked down. |
|
|